The simple observation entry is meant to be an abstract representation of many of
the observations used in this specification. It can be made concrete by the specification
of a few additional constraints, namely the vocabulary used for codes, and the value
representation. A simple observation may also inherit constraints from other specifications
(e.g., ASTM/HL7 Continuity of Care Document).
2017-07-18 Reverted to the original IHE specification of this template.
Note that this template was specified by IHE PCC. Find the referenced specification
here: https://art-decor.ihe-europe.net/art-decor/decor-templates--IHE-PCC-?section=templates&id=1.3.6.1.4.1.19376.1.5.3.1.4.13
Context
Parent nodes of template element with id 1.3.6.1.4.1.19376.1.5.3.1.4.13
These acts are simply observations that have occurred, and so are recored using the
<observation> element as shown above.
(Ention)
@classCode
cs
1 … 1
F
OBS
@moodCode
cs
1 … 1
F
EVN
hl7:templateId
II.EPSOS
1 … 1
M
(Ention)
@root
uid
1 … 1
F
1.3.6.1.4.1.19376.1.5.3.1.4.13
hl7:id
II.EPSOS
1 … 1
M
Each observation shall have an identifier.
(Ention)
hl7:code
CD
1 … 1
R
Observations shall have a code describing what was measured. The code system used
is determined by the vocabulary constraints on the types of measurements that might
be recorded in a section. Content modules that are derived from the Simple Observation
content module may restrict the code system and code values used for the observation.
(Ention)
hl7:text
ED
1 … 1
M
Each observation measurement entry may contain a <text> element providing the free
text that provides the same information as the observation within the narrative portion
of the document with a <text> element. For CDA based uses of Simple Observations,
this element SHALL be present, and SHALL contain a <reference> element that points
to the related string in the narrative portion of the document. For HL7 Version 3
based uses, the <text> element MAY be included.
(Ention)
hl7:statusCode
CS
1 … 1
M
The status code of all observations shall be completed.
(Ention)
@code
CONF
1 … 1
F
completed
hl7:effectiveTime
IVL_TS
1 … 1
R
The <effectiveTime> element shall be present in standalone observations , and shall
record the date and time when the measurement was taken. This element should be precise
to the day. If the date and time is unknown, this element should record that using
the nullFlavor attribute.
(Ention)
hl7:value
ANY
1 … *
R
The value of the observation shall be recording using a data type appropriate to the
observation. Content modules derived from the Simple Observation content module may
restrict the allowable data types used for the observation.