Date |
By |
Description |
2018‑04‑10 17:18:58 |
Mathias Ghys |
Official Release: v2.2.0 RC1
There have been changes to the following 13 issues since the last intermediate version
or release.
-
Issue 255 "country element in addr has to come from the epSOS country value set if available"
with status "Feedback needed". Last event (2018-01-11T16:53:34):
Dear Giorgio,
Thank you for the feedback. Very well appreciated. But could you provide me some clarification? To give you a little context on why I did this change: IHE Europe creates validators based on our ART-DECOR implementation guides. Before
the validator was based on the paper specifications in EXPAND. To identify the differences in validation results between the old validator and the
new ART-DECOR based one, a gap analysis was done between the two: For the Country, there was this difference that the old validator checked that the
value in the country element was coming from the epsosCountry value set. In ART-DECOR there was no rule for this. hl7:addr is of datatype AD.EPSOS and country is a subelement with datatype ADXP. I
wanted to indicate that the value of the country subelement has to come from the epsosCountry
value set. So that <country>IT</country> is allowed and not <country>ITALY</country>
What is the correct way to define this in ART-DECOR?
-
Issue 257 "added the templateId element" with status "Closed". Last event (2018-01-11T18:49:18):
Finding:
- added the templateId element
Suggestion:
-
Further explanation:
-
-
Issue 258 "Remove lock from template" with status "Closed". Last event (2018-01-12T09:37:36):
Finding:
- Can't edit template. Error message says: Template locked User Oliver Egger
2017-11-27
Suggestion:
-
Further explanation:
-
-
Issue 259 "No conformance set for ActiveIngredient substance name" with status "Open". Last
event (2018-04-05T11:51:38):
In the EXPAND PDF Spec this corresponds to R4.3, saying that this element is optional.
As the datatype is ST, using nullFlavor is not an option. However, in the code element
you also have the name.
-
Issue 260 "Change participant constraint text: replace inactive concept" with status "Closed".
Last event (2018-02-12T15:13:03):
Text adapted
-
Issue 261 "Add effectiveTime to EntryVitalSignsObservatoin" with status "Cancelled". Last event
(2018-03-02T10:57:06):
Duplicate of issue 263
-
Issue 262 "Adapt examples according to specification" with status "Closed". Last event (2018-03-14T16:18:31):
We received the confirmation in the semantic group in the meeting of 14/3 to change
the moodCode attribute and it has been adapted.
-
Issue 263 "Add effective time element to Vital Signs Observation" with status "Closed". Last
event (2018-03-28T11:07:56):
Effective type with datatype TS has been added to the Vital Signs Observation template. Issue is related to issue #266
-
Issue 264 "Add effective time element to Social History Observation" with status "Closed".
Last event (2018-03-26T17:19:16):
This topic was discussed at the Semantic WG tcon on 26/3/2018 and this is what has
been decided:
In the CDA IGs: we restrict the effectiveTime to onlyan interval (through the low/high
subelements) and we don't allow a specific timestamp (through the value attribute)
anymore. We improved the description and hope it will be more clear and less confusing.
Clinically it is meaningful, since it doesn't make sense to specify a single day for
smoking behaviour or alcohol consumption.
As a consequence, we only have to foresee the display of the low/high subelements
in the CDA Display tool.
-
Issue 265 "Add templateID 2.16.840.1.113883.10.20.1.54 to manifestation observation." with
status "Rejected". Last event (2018-03-28T11:02:57):
It was agreed upon to remove the dependency to the CCD template (2.16.840.1.113883.10.20.1.54)
from the allergies observation. No formal reason could be found to keep it. Since
the constraint was just in textual form, it won't be tested in the validation.
It's a spurious remaining from the IHE PCC, where conformance to CCD was requested.
No formal rules could be seen that could not be covered by other templates present
in the Allergy Reaction Observation.
-
Issue 266 "Change the datatype of the effectiveTime for the Vital Signs Organizer from IVL_TS
to TS" with status "Closed". Last event (2018-03-28T10:55:06):
Datatype is changed from IVL_TS to TS. This has been agreed upon in the working session with the eHDSI solution provider.
I also extended the description and added an example for clarification.
-
Issue 267 "Remove the textual constraint to the CCD template for the Allergies reaction observation"
with status "Closed". Last event (2018-03-28T10:52:56):
Textual constraint removed from the template. I also removed it from the example in the observation for the immunizations. Since
there it was not in the description, but only in the example and this is very confusing.
-
Issue 268 "Restrict effective Time in the entries of the Medical Devices Section" with status
"Closed". Last event (2018-04-05T12:02:55):
Changed the datatype for the effectiveTime in the Medical Devices Template from IVL_TS
to TS and adapted the description accordingly.
|
2018‑01‑10 17:19:30 |
Mathias Ghys |
Official Release: V2.1.2 RC
There have been changes to the following 20 issues since the last intermediate version
or release.
-
Issue 237 "Create scenario for this template" with status "Open". Last event (2017-11-20T18:27:02):
In order to make ART-DECOR create the Schematron files
-
Issue 238 "Create scenario for this template" with status "Open". Last event (2017-11-20T18:27:29):
In order to make ART-DECOR create the Schematron files
-
Issue 239 "Modify effectiveTime element for Medical Device template" with status "Feedback
needed". Last event (2017-11-23T20:51:26):
If we want the schematrons as intended, people _have_ to stick to the "usual" namespace
prefixes like...epsos
That is what Implementation Guides typically do, e.g. see IHE
-
Issue 240 "moodCode shall be INT" with status "In Progress". Last event (2017-11-24T13:36:16):
Finding:
-
There is an inconsistency between the
specification with OID 1.3.6.1.4.1.19376.1.5.3.1.4.3.1 in the older EXPAND
documentation (where the implementation guides were written in paper) where the
old validator was based upon and the current ART-DÉCOR definitions.
Suggestion:
- Change to moodCode=INT
Further explanation:
- I checked the PDF documentation, the parent template from IHE PCC 1.3.6.1.4.1.19376.1.5.3.1.4.3.1,
and the C-CDA template 2.16.840.1.113883.10.20.1.43
(see https://art-decor.ihe-europe.net/art-decor/decor-templates--IHE-PCC-?id=1.3.6.1.4.1.19376.1.5.3.1.4.3.1
)
Also see IHE PCC TF2 6.3.4.8.4: <act classCode='ACT' moodCode='INT'> The related statement is the intent (moodCode='INT') on how the related
entry is to be performed.
-
Issue 241 "inversionInd shall be true" with status "In Progress". Last event (2017-11-24T13:59:48):
Finding:
- no fixed value for inversion Ind
Suggestion:
- fixed inversionInd value true, according to IHE PCC 1.3.6.1.4.1.19376.1.5.3.1.4.7,
and epsos PDF specification
Further explanation:
-
-
Issue 242 "Fix duplicate OIDs in ART-DECOR" with status "Open". Last event (2017-11-29T12:39:09):
Finding:
We noticed that the same OIDs are used in ART-DECOR for defining different templates.
This originates from the older implementation guide definitions in the EXPAND period
and is a known issue for some time. The majority of conflicts arises from re-using templates from IHE PCC in epSOS, but
with additional constraints. I compared the list of templates in epsos: http://art-decor.org/art-decor/decor-template-ids--epsos- with the IHE PCC templates: https://art-decor.ihe-europe.net/art-decor/decor-template-ids--IHE-PCC-
I tried to list the templates where the OID is reused in epSOS:
- 1.3.6.1.4.1.19376.1.5.3.1.1.5.3.2 - Section Coded Vital Signs
- 1.3.6.1.4.1.19376.1.5.3.1.1.5.3.4 - Section Pregnancy History
- 1.3.6.1.4.1.19376.1.5.3.1.1.9.50 - Section Health Maintenance Care Plan
- 1.3.6.1.4.1.19376.1.5.3.1.3.6 - Section Active Problems
- 1.3.6.1.4.1.19376.1.5.3.1.3.8 - Section History of Past Illness
- 1.3.6.1.4.1.19376.1.5.3.1.3.12 - Section Coded List of Surgeries
- 1.3.6.1.4.1.19376.1.5.3.1.3.13 - Section Allergies and Other Adverse Reactions
- 1.3.6.1.4.1.19376.1.5.3.1.3.16.1 - Section Coded Social History
- 1.3.6.1.4.1.19376.1.5.3.1.3.17 - Section Functional Status
- 1.3.6.1.4.1.19376.1.5.3.1.3.23 - Section Immunizations
- 1.3.6.1.4.1.19376.1.5.3.1.4.1 - Severity
- 1.3.6.1.4.1.19376.1.5.3.1.4.1.1 - Entry Problem Status Observation
- 1.3.6.1.4.1.19376.1.5.3.1.4.1.2 - Entry Health Status Observation
- 1.3.6.1.4.1.19376.1.5.3.1.4.2 - Comment
- 1.3.6.1.4.1.19376.1.5.3.1.4.3 - epSOS Patient Medication Instructions
- 1.3.6.1.4.1.19376.1.5.3.1.4.3.1 - Entry Medication FulFillment Instructions
- 1.3.6.1.4.1.19376.1.5.3.1.4.4 - External Reference
- 1.3.6.1.4.1.19376.1.5.3.1.4.4.1 - Internal Reference
- 1.3.6.1.4.1.19376.1.5.3.1.4.5 - Problem
- 1.3.6.1.4.1.19376.1.5.3.1.4.5.2 - Problem Concern
- 1.3.6.1.4.1.19376.1.5.3.1.4.5.3 - Allergy and Intolerance Concern
- 1.3.6.1.4.1.19376.1.5.3.1.4.6 - Allergies And Intolerances
- 1.3.6.1.4.1.19376.1.5.3.1.4.7.2 - Immunization Product
- 1.3.6.1.4.1.19376.1.5.3.1.4.12 - Immunizations
- 1.3.6.1.4.1.19376.1.5.3.1.4.13 - Simple Observation
- 1.3.6.1.4.1.19376.1.5.3.1.4.13.1 - Vital Signs Organizer
- 1.3.6.1.4.1.19376.1.5.3.1.4.13.2 - Vital Signs Observation
- 1.3.6.1.4.1.19376.1.5.3.1.4.13.4 - Social History Observation
- 1.3.6.1.4.1.19376.1.5.3.1.4.13.5 - Pregnancy Observation
- 1.3.6.1.4.1.19376.1.5.3.1.4.13.6 - Blood Group
- 1.3.6.1.4.1.19376.1.5.3.1.4.19 - Procedure
Suggestion:
Change the OIDs. To what OIDs has to be discussed and maybe the change has to occur
by a change request.
Further explanation:
-
-
Issue 243 "Description of epsos:Ingredient is wrong" with status "Closed". Last event (2017-12-07T19:16:16):
Closed after having verified the solution with Konstantin Hyppönen.
-
Issue 244 "Fixed value for nullFlavor is inconsistent with description and former EXPAND documentation"
with status "Closed". Last event (2017-12-06T10:43:08):
- Conformance of Organisation changed from 1 ... 1 M to 1 ... 1 R
- nullFlavor fixed value for telecom element changed from 'UNK' to 'NI'
-
Issue 245 "Relax the constraint that the hl7:code shall be from value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.23
epSOSCodeProb (DYNAMIC)" with status "Closed". Last event (2017-12-08T17:09:24):
Just from a ART-DECOR definitional and validator perspective:
There are two, and after an intermediate release next week four, vocab binding strengths: Coded no exceptions = Required => violation will always throw an error. CNE is the
default, i.e. if none is specified, CNE is assumed. Coded with exceptions = extensible => violation will always throw an info Preferred => violation will always throw an info Example => violation will always throw an info
Hope this helps.
-
Issue 246 "Change cardinality of hl7:languageCode in recordTarget template" with status "Closed".
Last event (2017-12-08T12:19:27):
-
Issue 247 "Missing elements in epSOS CDA substanceAdministration template" with status "Open".
Last event (2017-12-15T17:09:12):
Finding:
- Some previously available constructs are missing:
- Number of packages
- Patient instructions
In the epSOS CDA IGs in ART/DECOR (comparison document) we find the following:
-
Add
the required element R4.8, Number of packages (Number of Packages) (
entry/substanceAdministration[templateId/[@root='1.3.6.1.4.1.12559.11.10.1.3.1.3.2']/entryRelationship[@typeCode='COMP']/
supply[@moodCode= 'RQO' and independentInd/@value='false']/quantity)
This is indicated as "ALL DONE"
Nothing is set in this document about the patient Instructions
Suggestion:
-
Further explanation:
-
-
Issue 248 "hl7:name cardinality must be changed from 0 ... 1 to 1 ... 1" with status "Open".
Last event (2017-12-18T10:50:39):
Finding:
- outcome of gap analysis of Abderrazek: consumable/manufacturedProduct/manufacturedMaterial/name required. In Expand the Cardinality
is for the element is: (eP/eD/PS: R/NA/NA).
Suggestion:
- Change the cardinality from 0 ... 1 to 1 ... 1
Further explanation:
-
-
Issue 249 "Set Telecom element in line with usages in other templates" with status "Closed".
Last event (2018-01-05T16:58:21):
Fixed the Telecom element, but I didn't create a separate Template yet...
-
Issue 250 "telecom use code" with status "Open". Last event (2018-01-08T11:46:08):
Finding:
- telecom @use is required, but should be optional, according to text.
Suggestion:
- change cardinality to 0...1 (as in other occurences of telecom)
Further explanation:
-
-
Issue 251 "telecom nullFlavor value" with status "Open". Last event (2018-01-08T11:52:44):
Finding:
- to be changed from UNK to NI
Suggestion:
-
Further explanation:
-
-
Issue 252 "Add nullFlavor possibility with NI fixed value to Telecom element" with status "Closed".
Last event (2018-01-08T17:19:23):
-
Issue 253 "Adapt conformancy of family and given elements conform the EXPAND specifications"
with status "Feedback needed". Last event (2018-01-09T12:38:14):
OK. I removed the contain statement.
Note that the intention to make those fields mandatory will fail if not all enclosing
elements are also mandatory. Otherwise, the sender can just use a nullFlavor on one
of the enclosing levels.
-
Issue 254 "Adapt Telecom element with relation to other elements" with status "Closed". Last
event (2018-01-10T09:38:56):
Changed according to requirement R1.10.8 in the EXPAND documentation
-
Issue 255 "country element in addr has to come from the epSOS country value set if available"
with status "Closed". Last event (2018-01-10T16:19:27):
Added the constraint
-
Issue 256 "Change Conformance of HCP assignedPerson family and given name according to documentation"
with status "Closed". Last event (2018-01-10T16:15:35):
I processed the changes
|
2017‑11‑17 11:09:31 |
Mathias Ghys |
Official Release: V2.1.1
There have been changes to the following 200 issues since the last intermediate version
or release.
|
2015‑11‑07 15:17:27 |
Dr. Kai U. Heitmann |
Official Release: 2014 Intermediate release before changes during the EXPAND update and review project: Formalization
of epSOS Patient Summary, ePrescription and eDispensation documents using ART-DECOR
|
2014‑02‑28 |
Dr. Kai U. Heitmann (Nictiz) |
Corrected several templates that contained illegal spaces in OIDs or codes |
2013‑12‑03 |
Alexander Henket (Nictiz) |
Review version for Giorgio Cangioli |
2013‑06‑09 |
Alexander Henket (Nictiz) |
Extended data set, vocabulary, templates |
2013‑06‑04 |
Tessa van Stijn (Nictiz) |
Added scenario and HL7 templates |
2013‑05‑30 |
Maarten Ligtvoet (Nictiz) |
First concept of the epSOS decor file for demonstration purposes |
2013‑05‑30 |
Elze de Groot (Nictiz) |
Added data set and vocabulary |
|