DECOR Information for Project: epSOS (epsos-)

Project Information

epSOS in ART-DECOR

This representation of epSOS does not replace the normative specification found at http://www.epsos.eu, but is intended as the basis for future developments based on the epSOS specifications.

About epSOS

epSOS aims to design, build and evaluate a service infrastructure that demonstrates cross-border interoperability between electronic health record systems in Europe.

Cross-border eHealth Services

epSOS attempts to offer seamless healthcare to European citizens. Key goals are to improve the quality and safety of healthcare for citizens when travelling to another European country. Moreover, it concentrates on developing a practical eHealth framework and ICT infrastructure that enables secure access to patient health information among different European healthcare systems. epSOS can make a significant contribution to patient safety by reducing the frequency of medical errors and by providing quick access to documentation. In emergency situations, this documentation provides the medical personnel with life-saving information and reduces the (sometimes needless) repetition of diagnostic procedures. The technical, legal and organizational concepts developed within the framework of the project are subject to an extensive practical testing phase over a period of one year. epSOS will test cross-border eHealth services in the following areas: In a first phase:

Notes for reading this specification:

Please note: The transcription to ART-DECOR of the normative master specification for epSOS was originally done by the Dutch National IT Institute for Health Care (Nictiz) end of 2013 / beginning of 2014 as part of an official agreement between the epSOS project and Nictiz.

The specification as of now is the result of a review of the original epSOS specification. This was done within the EXPAND project WP5, before moving the specification to CEG. The activity was supported by HL7 International / HL7 International Foundation / HL7 Europe.

Additional project information

noticeThis project is marked as a repository
Properties
Prefix: epsos-Default language: en-USrepositoryContains reusable content?
Publication location Project overview
http://epsos.art-decor.org/ Project index
Disclaimer
The content of this publication has been carefully prepared and reviewed. However, epSOS, ESNA, LOMBARDY, ELGA, CLM, GIPDMP, Industry Team, NICTIZ, NHS, ZI, FHGISST, MEDCOM, IZIP, SALAR, NHIC, CATA, DENA, Gematik and FRNA does not guarantee the accuracy, completeness or quality of the information provided, or that it is up-to-date. Liability claims against epSOS, ESNA, LOMBARDY, ELGA, CLM, GIPDMP, Industry Team, NICTIZ, NHS, ZI, FHGISST, MEDCOM, IZIP, SALAR, NHIC, CATA, DENA, Gematik and FRNA in respect of material or immaterial damage caused by the use or non-use of the information offered or by inaccurate or incomplete information are in principle ruled out provided that there is no provable culpable intent or gross negligence on the institute’s part.
List of Authors
  • Tessa van Stijn
  • Elze de Groot
  • Maarten Ligtvoet
  • Alexander Henket
  • Giorgio Cangioli
  • Dr. Kai U. Heitmann
  • Dr. Stefan Sabutsch
  • Christof Gessner
  • Libor Seidl
  • Catherine Chronaki
  • Marta Terrón Cuadrado
  • Jérôme Subiger
  • Renaud Subiger
  • Mathias Ghys
  • Licínio Krusta Mano
  • Christophe Dumont
  • Yacoubou Waolany

Version Info

Date By Description
2018‑04‑10 17:18:58 Mathias Ghys Official Release: v2.2.0 RC1
There have been changes to the following 13 issues since the last intermediate version or release.
  • Issue 255 "country element in addr has to come from the epSOS country value set if available" with status "Feedback needed". Last event (2018-01-11T16:53:34):
    Dear Giorgio,

    Thank you for the feedback. Very well appreciated. But could you provide me some clarification?
    To give you a little context on why I did this change:
    IHE Europe creates validators based on our ART-DECOR implementation guides. Before the validator was based on the paper specifications in EXPAND.
    To identify the differences in validation results between the old validator and the new ART-DECOR based one, a gap analysis was done between the two:
    For the Country, there was this difference that the old validator checked that the value in the country element was coming from the epsosCountry value set.
    In ART-DECOR there was no rule for this.
    hl7:addr is of datatype AD.EPSOS and country is a subelement with datatype ADXP. I wanted to indicate that the value of the country subelement has to come from the epsosCountry value set.
    So that <country>IT</country> is allowed and not <country>ITALY</country>

    What is the correct way to define this in ART-DECOR?


  • Issue 257 "added the templateId element" with status "Closed". Last event (2018-01-11T18:49:18):
    Finding:

    - added the templateId element

    Suggestion:

    -

    Further explanation:

    -

  • Issue 258 "Remove lock from template" with status "Closed". Last event (2018-01-12T09:37:36):
    Finding:

    - Can't edit template. Error message says: Template locked User Oliver Egger 2017-11-27

    Suggestion:

    -

    Further explanation:

    -

  • Issue 259 "No conformance set for ActiveIngredient substance name" with status "Open". Last event (2018-04-05T11:51:38):
    In the EXPAND PDF Spec this corresponds to R4.3, saying that this element is optional. As the  datatype is ST, using nullFlavor is not an option. However, in the code element you also have the name.
  • Issue 260 "Change participant constraint text: replace inactive concept" with status "Closed". Last event (2018-02-12T15:13:03):
    Text adapted
  • Issue 261 "Add effectiveTime to EntryVitalSignsObservatoin" with status "Cancelled". Last event (2018-03-02T10:57:06):
    Duplicate of issue 263
  • Issue 262 "Adapt examples according to specification" with status "Closed". Last event (2018-03-14T16:18:31):
    We received the confirmation in the semantic group in the meeting of 14/3 to change the moodCode attribute and it has been adapted.
  • Issue 263 "Add effective time element to Vital Signs Observation" with status "Closed". Last event (2018-03-28T11:07:56):
    Effective type with datatype TS has been added to the Vital Signs Observation template.
    Issue is related to issue #266
  • Issue 264 "Add effective time element to Social History Observation" with status "Closed". Last event (2018-03-26T17:19:16):
    This topic was discussed at the Semantic WG tcon on 26/3/2018 and this is what has been decided:
    In the CDA IGs: we restrict the effectiveTime to onlyan interval (through the low/high subelements) and we don't allow a specific timestamp (through the value attribute) anymore. We improved the description and hope it will be more clear and less confusing.
    Clinically it is meaningful, since it doesn't make sense to specify a single day for smoking behaviour or alcohol consumption.
    As a consequence, we only have to foresee the display of the low/high subelements in the CDA Display tool.
  • Issue 265 "Add templateID 2.16.840.1.113883.10.20.1.54 to manifestation observation." with status "Rejected". Last event (2018-03-28T11:02:57):
    It was agreed upon to remove the dependency to the CCD template (2.16.840.1.113883.10.20.1.54) from the allergies observation. No formal reason could be found to keep it. Since the constraint was just in textual form, it won't be tested in the validation.

    It's a spurious remaining from the IHE PCC, where conformance to CCD was requested. No formal rules could be seen that could not be covered by other templates present in the Allergy Reaction Observation.


  • Issue 266 "Change the datatype of the effectiveTime for the Vital Signs Organizer from IVL_TS to TS" with status "Closed". Last event (2018-03-28T10:55:06):
    Datatype is changed from IVL_TS to TS.
    This has been agreed upon in the working session with the eHDSI solution provider. I also extended the description and added an example for clarification.
  • Issue 267 "Remove the textual constraint to the CCD template for the Allergies reaction observation" with status "Closed". Last event (2018-03-28T10:52:56):
    Textual constraint removed from the template.
    I also removed it from the example in the observation for the immunizations. Since there it was not in the description, but only in the example and this is very confusing.
  • Issue 268 "Restrict effective Time in the entries of the Medical Devices Section" with status "Closed". Last event (2018-04-05T12:02:55):
    Changed the datatype for the effectiveTime in the Medical Devices Template from IVL_TS to TS and adapted the description accordingly.
2018‑01‑10 17:19:30 Mathias Ghys Official Release: V2.1.2 RC
There have been changes to the following 20 issues since the last intermediate version or release.
  • Issue 237 "Create scenario for this template" with status "Open". Last event (2017-11-20T18:27:02):
    In order to make ART-DECOR create the Schematron files
  • Issue 238 "Create scenario for this template" with status "Open". Last event (2017-11-20T18:27:29):
    In order to make ART-DECOR create the Schematron files
  • Issue 239 "Modify effectiveTime element for Medical Device template" with status "Feedback needed". Last event (2017-11-23T20:51:26):
    If we want the schematrons as intended, people _have_ to stick to the "usual" namespace prefixes like...epsos

    That is what Implementation Guides typically do, e.g. see IHE
  • Issue 240 "moodCode shall be INT" with status "In Progress". Last event (2017-11-24T13:36:16):
    Finding:

    -

    There is an inconsistency between the specification with OID 1.3.6.1.4.1.19376.1.5.3.1.4.3.1 in the older EXPAND documentation (where the implementation guides were written in paper) where the old validator was based upon and the current ART-DÉCOR definitions.

    Suggestion:

    - Change to moodCode=INT

    Further explanation:

    - I checked the PDF documentation, the parent template from IHE PCC 1.3.6.1.4.1.19376.1.5.3.1.4.3.1, and the C-CDA template 2.16.840.1.113883.10.20.1.43

    (see https://art-decor.ihe-europe.net/art-decor/decor-templates--IHE-PCC-?id=1.3.6.1.4.1.19376.1.5.3.1.4.3.1 )

    Also see IHE PCC TF2  6.3.4.8.4:
     <act  classCode='ACT' moodCode='INT'>
    The  related  statement   is  the  intent   (moodCode='INT')  on  how  the  related  entry  is  to  be 
    performed.


  • Issue 241 "inversionInd shall be true" with status "In Progress". Last event (2017-11-24T13:59:48):
    Finding:

    - no fixed value for inversion Ind

    Suggestion:

    - fixed inversionInd value true, according to IHE PCC 1.3.6.1.4.1.19376.1.5.3.1.4.7, and epsos PDF specification

    Further explanation:

    -

  • Issue 242 "Fix duplicate OIDs in ART-DECOR" with status "Open". Last event (2017-11-29T12:39:09):
    Finding:

    We noticed that the same OIDs are used in ART-DECOR for defining different templates. This originates from the older implementation guide definitions in the EXPAND period and is a known issue for some time.
    The majority of conflicts arises from re-using templates from IHE PCC in epSOS, but with additional constraints.
    I compared the list of templates in epsos: http://art-decor.org/art-decor/decor-template-ids--epsos-
    with the IHE PCC templates: https://art-decor.ihe-europe.net/art-decor/decor-template-ids--IHE-PCC-

    I tried to list the templates where the OID is reused in epSOS:

    • 1.3.6.1.4.1.19376.1.5.3.1.1.5.3.2 - Section Coded Vital Signs
    • 1.3.6.1.4.1.19376.1.5.3.1.1.5.3.4 - Section Pregnancy History
    • 1.3.6.1.4.1.19376.1.5.3.1.1.9.50 - Section Health Maintenance Care Plan
    • 1.3.6.1.4.1.19376.1.5.3.1.3.6 - Section Active Problems
    • 1.3.6.1.4.1.19376.1.5.3.1.3.8 - Section History of Past Illness
    • 1.3.6.1.4.1.19376.1.5.3.1.3.12 - Section Coded List of Surgeries
    • 1.3.6.1.4.1.19376.1.5.3.1.3.13 - Section Allergies and Other Adverse Reactions
    • 1.3.6.1.4.1.19376.1.5.3.1.3.16.1 - Section Coded Social History
    • 1.3.6.1.4.1.19376.1.5.3.1.3.17 - Section Functional Status
    • 1.3.6.1.4.1.19376.1.5.3.1.3.23 - Section Immunizations
    • 1.3.6.1.4.1.19376.1.5.3.1.4.1 - Severity
    • 1.3.6.1.4.1.19376.1.5.3.1.4.1.1 - Entry Problem Status Observation
    • 1.3.6.1.4.1.19376.1.5.3.1.4.1.2 - Entry Health Status Observation
    • 1.3.6.1.4.1.19376.1.5.3.1.4.2 - Comment
    • 1.3.6.1.4.1.19376.1.5.3.1.4.3 - epSOS Patient Medication Instructions
    • 1.3.6.1.4.1.19376.1.5.3.1.4.3.1 - Entry Medication FulFillment Instructions
    • 1.3.6.1.4.1.19376.1.5.3.1.4.4 - External Reference
    • 1.3.6.1.4.1.19376.1.5.3.1.4.4.1 - Internal Reference
    • 1.3.6.1.4.1.19376.1.5.3.1.4.5 - Problem
    • 1.3.6.1.4.1.19376.1.5.3.1.4.5.2 - Problem Concern
    • 1.3.6.1.4.1.19376.1.5.3.1.4.5.3 - Allergy and Intolerance Concern
    • 1.3.6.1.4.1.19376.1.5.3.1.4.6 - Allergies And Intolerances
    • 1.3.6.1.4.1.19376.1.5.3.1.4.7.2 - Immunization Product
    • 1.3.6.1.4.1.19376.1.5.3.1.4.12 - Immunizations
    • 1.3.6.1.4.1.19376.1.5.3.1.4.13 - Simple Observation
    • 1.3.6.1.4.1.19376.1.5.3.1.4.13.1 - Vital Signs Organizer
    • 1.3.6.1.4.1.19376.1.5.3.1.4.13.2 - Vital Signs Observation
    • 1.3.6.1.4.1.19376.1.5.3.1.4.13.4 - Social History Observation
    • 1.3.6.1.4.1.19376.1.5.3.1.4.13.5 - Pregnancy Observation
    • 1.3.6.1.4.1.19376.1.5.3.1.4.13.6 - Blood Group
    • 1.3.6.1.4.1.19376.1.5.3.1.4.19 - Procedure
    Suggestion:

    Change the OIDs. To what OIDs has to be discussed and maybe the change has to occur by a change request.

    Further explanation:

    -

  • Issue 243 "Description of epsos:Ingredient is wrong" with status "Closed". Last event (2017-12-07T19:16:16):
    Closed after having verified the solution with Konstantin Hyppönen.
  • Issue 244 "Fixed value for nullFlavor is inconsistent with description and former EXPAND documentation" with status "Closed". Last event (2017-12-06T10:43:08):
    • Conformance of Organisation changed from 1 ... 1 M to 1 ... 1 R
    • nullFlavor fixed value for telecom element changed from 'UNK' to 'NI'

  • Issue 245 "Relax the constraint that the hl7:code shall be from value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.23 epSOSCodeProb (DYNAMIC)" with status "Closed". Last event (2017-12-08T17:09:24):
    Just from a ART-DECOR definitional and validator perspective:

    There are two, and after an intermediate release next week four, vocab binding strengths:
    Coded no exceptions = Required => violation will always throw an error. CNE is the default, i.e. if none is specified, CNE is assumed.
    Coded with exceptions = extensible => violation will always throw an info
    Preferred => violation will always throw an info
    Example => violation will always throw an info

    Hope this helps.
  • Issue 246 "Change cardinality of hl7:languageCode in recordTarget template" with status "Closed". Last event (2017-12-08T12:19:27):
  • Issue 247 "Missing elements in epSOS CDA substanceAdministration template" with status "Open". Last event (2017-12-15T17:09:12):
    Finding:

    - Some previously available constructs are missing:

    • Number of packages
    • Patient instructions
    In the epSOS CDA IGs in ART/DECOR (comparison document) we find the following:

    • Add the required element R4.8, Number of packages (Number of Packages) ( entry/substanceAdministration[templateId/[@root='1.3.6.1.4.1.12559.11.10.1.3.1.3.2']/entryRelationship[@typeCode='COMP']/ supply[@moodCode= 'RQO' and independentInd/@value='false']/quantity)
    This is indicated as "ALL DONE"

    Nothing is set in this document about the patient Instructions


    Suggestion:

    -

    Further explanation:

    -

  • Issue 248 "hl7:name cardinality must be changed from 0 ... 1 to 1 ... 1" with status "Open". Last event (2017-12-18T10:50:39):
    Finding:  

    - outcome of gap analysis of Abderrazek: consumable/manufacturedProduct/manufacturedMaterial/name required. In Expand the Cardinality is for the element is: (eP/eD/PS: R/NA/NA).

    Suggestion:

    - Change the cardinality from 0 ... 1 to 1 ... 1

    Further explanation:

    -

  • Issue 249 "Set Telecom element in line with usages in other templates" with status "Closed". Last event (2018-01-05T16:58:21):
    Fixed the Telecom element, but I didn't create a separate Template yet...
  • Issue 250 "telecom use code" with status "Open". Last event (2018-01-08T11:46:08):
    Finding:

    - telecom @use is required, but should be optional, according to text.

    Suggestion:

    - change cardinality to 0...1 (as in other occurences of telecom)

    Further explanation:

    -

  • Issue 251 "telecom nullFlavor value" with status "Open". Last event (2018-01-08T11:52:44):
    Finding:

    - to be changed from UNK to NI

    Suggestion:

    -

    Further explanation:

    -

  • Issue 252 "Add nullFlavor possibility with NI fixed value to Telecom element" with status "Closed". Last event (2018-01-08T17:19:23):
  • Issue 253 "Adapt conformancy of family and given elements conform the EXPAND specifications" with status "Feedback needed". Last event (2018-01-09T12:38:14):
    OK. I removed the contain statement.

    Note that the intention to make those fields mandatory will fail if not all enclosing elements are also mandatory. Otherwise, the sender can just use a nullFlavor on one of the enclosing levels.
  • Issue 254 "Adapt Telecom element with relation to other elements" with status "Closed". Last event (2018-01-10T09:38:56):
    Changed according to requirement R1.10.8 in the EXPAND documentation
  • Issue 255 "country element in addr has to come from the epSOS country value set if available" with status "Closed". Last event (2018-01-10T16:19:27):
    Added the constraint
  • Issue 256 "Change Conformance of HCP assignedPerson family and given name according to documentation" with status "Closed". Last event (2018-01-10T16:15:35):
    I processed the changes
2017‑11‑17 11:09:31 Mathias Ghys Official Release: V2.1.1
There have been changes to the following 200 issues since the last intermediate version or release.
  • Issue 2 "Add laparoscopic colectomy" with status "Open". Last event (2016-03-29T13:36:09):
    To be considered for Next MVC version
  • Issue 24 "Value set epSOSCodeProb without dataset binding" with status "Closed". Last event (2016-03-17T17:46:53):
  • Issue 31 "Value set epSOSPersonalRelationship without dataset binding" with status "Closed". Last event (2016-03-17T17:53:46):
    Modified the binding for the /ClinicalDocument/participant/associatedEntity/code 
  • Issue 32 "Value set epSOSRoleClass without dataset binding" with status "Closed". Last event (2016-03-17T17:59:20):
    this value set is bound to   CDA.participant.AssociatedEntity.classCode
  • Issue 33 "Value set epSOSTimingAddress without dataset binding" with status "Closed". Last event (2016-03-17T18:04:08):
    used in the telecom/@use attribute
  • Issue 37 "Value set epSOSDisplayLabel without dataset binding" with status "Rejected". Last event (2016-03-17T18:04:36):
  • Issue 38 "Two different descriptions in the documentation" with status "Open". Last event (2016-03-17T17:57:26):
  • Issue 39 "Element Indication" with status "Deferred". Last event (2017-05-17T14:36:22):
    Any analysis about the dataset is deferred
  • Issue 42 "Status" with status "Closed". Last event (2016-03-29T17:36:26):
    Changed the status code description for SubstaceAdministration
  • Issue 43 "Name of the concept" with status "Deferred". Last event (2016-03-29T13:24:34):
    HCER and MRO are not priority for the time being (not part of the guidelines)

    Data set element should be revised accoridng to the EU guidelines

  • Issue 47 "Missing value set binding for Health Care Alert code" with status "Closed". Last event (2016-04-22T09:16:13):
    Added the specification text to the comment field of the parent data element container
  • Issue 48 "Missing value set binding for Treatment code" with status "Closed". Last event (2016-04-04T15:28:28):
    No value set binding needed at this point in time.
  • Issue 49 "Missing value set binding for Prescriber Speciality" with status "Closed". Last event (2016-04-04T15:27:50):
    Mentioned HP Specialty is sufficient for now. Not value set binding necessary.
  • Issue 50 "Missing concepts for Dispenser?" with status "Closed". Last event (2016-03-29T13:21:57):
  • Issue 51 "Specialization of template "1.3.6.1.4.1.19376.1.5.3.1.2.4"" with status "Open". Last event (2016-07-13T16:57:24):
  • Issue 52 "Cardinality/nullFlavor for address (parts)" with status "Closed". Last event (2017-05-17T14:44:00):
    This is handled by the AD.EPSOS specialization of the AD datatype
  • Issue 53 "HP can have only 1 relevant speciality in a given context" with status "Open". Last event (2016-03-17T17:42:05):
  • Issue 54 "MRO has impossible card on performer/assignedEntity" with status "Rejected". Last event (2016-03-17T17:08:20):
    No fix required for the DECOR template.
  • Issue 55 "Assignement of an epSOS template ID for this section" with status "Open". Last event (2016-07-13T14:52:49):
  • Issue 56 "Identification of the IHE PCC template version actually used" with status "Closed". Last event (2016-04-04T16:09:57):
    Checked
  • Issue 57 "Informant role" with status "Open". Last event (2016-07-13T14:54:45):
  • Issue 58 "Assign an epSOS specific template ID" with status "Open". Last event (2016-07-13T14:51:30):
  • Issue 59 "Optionaly of template IDs" with status "Open". Last event (2015-11-09T15:26:26):
    Finding:

    The current specs requires that all the IHE PCC (simple obs ad socila Obs) and the CCD template IDs are provided .

    IHE PCC template just says that "These <templateId> elements identify this as a Social History observation." without indicating any optionality.

    Suggestion:

    Evaluate if is really needed that all of them would be required.

    Further explanation:

    This applies to several other templates

  • Issue 60 "Update example" with status "Closed". Last event (2017-05-17T14:39:29):
    removed the not used elements
  • Issue 61 "types of social observation" with status "Open". Last event (2015-11-09T15:43:47):
    Finding:

    the conceptual model consider only three types of social observation:

    • Smoke
    • Alcohol

    • Diet

    Suggestion:

    Evaluate if we need to specialize the IHE PCC template considering three different specialized template for each of them

    Further explanation:

    in the case of diet a coded element is excpected in the obs.value , but the epSSO MVC doesn't define such a type of value set

  • Issue 62 "Relationship between the type of obs.code and type of obs.value " with status "Open". Last event (2016-07-13T14:53:06):
  • Issue 63 "version of referenced specification" with status "Closed". Last event (2016-03-29T17:02:51):
    versions of the IHE TFs have been updated
  • Issue 64 "Assign an epSOS specific template ID" with status "Open". Last event (2017-08-01T19:05:36):
    I support this. id is mandatory in IHE template, but this does not make sense here (changed it to 0..1 R).
  • Issue 65 "routeofAdm and apporach site" with status "Closed". Last event (2017-05-17T13:52:29):
    Removed the binding 
  • Issue 66 "approachSiteCode" with status "Closed". Last event (2017-05-17T14:13:26):
    the approachSiteCode seems to be no more in the template...assumed closed
  • Issue 67 "doseQuantity duplicated" with status "Closed". Last event (2015-11-19T15:56:37):
    doseQuantity is now only one element with data type RTO_PQ_PQ
  • Issue 68 " 2.16.840.1.113883.10.20.1.46 Position Of Vaccination" with status "Closed". Last event (2016-03-17T11:26:57):
    Element removed
  • Issue 69 " adverse reactions in immunization" with status "Closed". Last event (2016-02-23T13:17:25):
  • Issue 70 "Product information duplicated ?" with status "Closed". Last event (2016-03-17T17:39:43):
    removed the "duplicated" relationship with product
  • Issue 71 "manufacturerOrganization in immunization product" with status "Closed". Last event (2015-11-19T16:01:42):
    manufacturerOrganization element eliminated
  • Issue 72 "Update the value sets based on latest MVC" with status "Closed". Last event (2017-11-15T16:14:01):
    Solved by loading the latest MVC version 2.2.2
  • Issue 73 "Revision of Section Coded Results" with status "Closed". Last event (2016-07-13T17:05:47):
    Template ID updated
  • Issue 74 "Revision of Section Allergies and Other Adverse Reactions" with status "Closed". Last event (2015-12-30T15:30:09):
    1.3.6.1.4.1.19376.1.5.3.1.4.5.3 Allergy and Intolerance Concern
    • statusCode shall be active|suspended|aborted|completed only, while whole Value Sets ActStatus is bound. Corrected.
    1.3.6.1.4.1.19376.1.5.3.1.4.6 Allergies And Intolerances
    • Allergen (participant typeCode CSM) is conditional 0..* to Observation.value. Condition added :: Omit if Observation.value is SNOMED-CT 160244002 No known Allergies
  • Issue 75 "Revision of Sections History of Past Illness and Active Problems" with status "Closed". Last event (2015-11-23T16:36:46):
  • Issue 76 "Revision of Section Coded List of Surgeries" with status "Closed". Last event (2017-05-17T13:49:54):
  • Issue 77 "Revision of Section Medical Devices Coded" with status "Closed". Last event (2017-08-01T18:46:34):
    IHE 1.3.6.1.4.1.19376.1.5.3.1.1.5.3.5 actually reauires section.id
  • Issue 78 "Revision of Section Health Maintenance Care Plan" with status "Closed". Last event (2016-03-18T15:07:15):
    the actual optionality of this template id is not well specified neither in the IHE PCC nor in the epSOS specs.

    The schematron published by IHE requires this element for the IHE PCC template. Change the cardinality from 0..1 to 1..1
  • Issue 79 "Revision of Section Functional Status" with status "Closed". Last event (2015-11-21T16:32:42):
    Section revised
  • Issue 80 "Revision of Section Pregnancy History" with status "Closed". Last event (2016-04-04T14:41:36):
    Reviewed Templates and pending issues, added a few new issues.
    Revision is closed.
  • Issue 81 "Revision of Section Coded Vital Signs" with status "Closed". Last event (2016-03-17T10:53:01):
  • Issue 82 "Revision section Coded Results" with status "Cancelled". Last event (2015-11-25T11:22:52):
    duplicated item
  • Issue 83 "DoseQuantity DT to be fixed" with status "Closed". Last event (2015-11-24T18:48:27):
    This was definitely entered/defined in error. doseQuantity is now a IVL_PQ as defined in the generic CDA.
  • Issue 84 "No Value Set for coding Invalidity" with status "Open". Last event (2015-11-21T16:29:47):
    Finding:

    This is a known issue. No Value set have been identified for describing autonomy/invalidity

    Suggestion:

    -

    Further explanation:

    -

  • Issue 85 "Concern entry ID" with status "Closed". Last event (2017-05-17T14:09:48):
    changed to required
  • Issue 86 "concern entri statuscode voc binding" with status "Closed". Last event (2017-05-17T14:08:31):
    added new value set and binding
  • Issue 87 "Constrains on IVL_TS" with status "Closed". Last event (2015-11-30T16:39:52):
    Fixed
  • Issue 88 "negationInd" with status "Closed". Last event (2016-04-04T16:08:29):
    Added negationInd isOptional=true
  • Issue 89 "Data type of the obs.code" with status "Closed". Last event (2017-05-17T12:22:07):
    datatypes updated
  • Issue 90 "check obs.ocde voc binding" with status "Open". Last event (2016-07-13T16:42:39):
  • Issue 91 "value set binding for Obs.value" with status "Open". Last event (2016-07-13T14:52:31):
  • Issue 92 "the referenced entry ID to be updated" with status "Open". Last event (2016-07-13T16:42:59):
  • Issue 93 "add attributes to the entryRelationship" with status "Closed". Last event (2015-11-23T12:39:36):
    Agree, done
  • Issue 94 "severity: the text shall contain a ref " with status "Closed". Last event (2015-11-23T12:42:23):
    Agree, done
  • Issue 95 "statusCode required ?" with status "Closed". Last event (2015-12-30T15:27:39):
    statusCode shall be present in all cases and values "completed" due to the underlying (derived from) specifications; Changes in the templates.
  • Issue 96 "obs.value add constrains" with status "Closed". Last event (2015-11-25T11:25:25):
    data type changed to CD.EPSOS
  • Issue 97 "assign an epSOS template ID" with status "Open". Last event (2016-07-13T16:43:22):
  • Issue 98 "Text element: add constrain" with status "Closed". Last event (2015-12-30T15:03:16):
    Done
  • Issue 99 "Comment Author" with status "Open". Last event (2016-07-13T14:51:51):
  • Issue 100 "rename to "Medication Item""" with status "Closed". Last event (2015-11-24T18:53:57):
    The Template's business name and display name has been set accordingly
  • Issue 101 "templates for Normal Dosing, split dosing and combination medication" with status "Deferred". Last event (2017-05-17T13:54:38):
    In case to be reconsidered for future discussion
  • Issue 102 "Medication entry cardinality" with status "Closed". Last event (2015-11-25T11:05:15):
    entry changed to 1..* R
  • Issue 103 "Revision of Section Medication Summary" with status "Closed". Last event (2016-03-01T12:31:10):
  • Issue 104 "Text in description" with status "Deferred". Last event (2016-03-17T17:27:45):
    This an optional section used to say i know she is pregnant. Up to now all the oter cases has been managed skipping the section.

    The way to manage negations, not known information need to be faced more widely. 
  • Issue 105 "section code correct?" with status "Deferred". Last event (2015-11-25T11:18:04):
  • Issue 106 "should-language" with status "Closed". Last event (2015-11-25T11:04:09):
    The code is thus declared to be mandatory 1..1 M, ie no null flavors are allowed. That is correct in spec and ART-DECOR.

    The phrase "the code should come from this list" equals to a binding to the value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.9 epSOSPregnancyInformation (Dynamic) with CWE coding strength (coded with exceptions), saying that if a concept fits one of the codes in the value set this code must be used, otherwise other codes may be used (from other code systems).

    Changed codings strength to CWE
  • Issue 107 "cardinality observation/value" with status "Closed". Last event (2015-11-25T11:03:18):
    Then the spec needs to be corrected.
    M means no null flavors are allowed (mandatory). This is in principal equal to SHALL.
    R means null flavors are allowed (required).
    Null Flavors should be allowed here for sure.

    Changed to 1..1 R
  • Issue 108 "section code is for document, details to be added" with status "Open". Last event (2015-11-25T11:02:56):
    Finding:

    - The LOINC code used here signifies a document, not a section. Furthermore, it asks for specification of {setting} and {Author Type}. Not sure if this is appropriate code here.

    Suggestion:

    - Check for alternative, possibly request new code from LOINC

    Further explanation:

    -

  • Issue 109 "restriction to past surgeries" with status "Deferred". Last event (2017-05-17T13:49:37):
    To be reconsidered in the future
  • Issue 110 "cardinality of Procedure entry" with status "Closed". Last event (2015-11-26T16:35:29):
    Added this text to Procedure entry
  • Issue 111 "Change Section.code to be standard" with status "Closed". Last event (2015-11-25T11:12:27):
    Was entered in ART-DECOR in error, is now the correct LOINC code for Section.code
  • Issue 112 "effectiveTime mandatory, NullFlavor not allowed? discussion needed" with status "Closed". Last event (2015-11-26T15:57:07):
    Done
  • Issue 113 "Missing id in template" with status "Closed". Last event (2015-11-25T13:00:10):
    Element id added as 0..* R
  • Issue 114 "Code no value set bound" with status "Closed". Last event (2015-11-25T13:01:03):
    Observation.code now bound to epSOSBloodPressure value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.21
  • Issue 115 "More codes in value set" with status "Open". Last event (2015-11-25T12:39:27):
    Finding:

    Only a few concepts in associated value set Obs.code

    Suggestion:

    In the future a value set should contain much more concepts, see e.g. ELGA_Vitalparameterarten 1.2.40.0.34.10.34

    Further explanation:

    -

  • Issue 116 "Add text element" with status "Closed". Last event (2015-11-26T15:51:40):
    Done
  • Issue 117 "statusCode missing" with status "Closed". Last event (2015-11-26T15:35:19):
    Done
  • Issue 118 "Use of methodCode and targetSiteCode" with status "Closed". Last event (2016-03-29T16:51:44):
    Those elements had value sets associated. They were included in the template, but not accepted by functional experts as part of the Patient Summary data set.

    Left as optional element without voc bunding only for future consideration. Added a note in the template description.
  • Issue 119 "Multiplicity in EntrySimpleObservation" with status "Closed". Last event (2015-11-26T15:19:25):
    Done as planned
  • Issue 120 "Update the actStatus" with status "Closed". Last event (2017-05-17T14:33:44):
    defined a new VS and added a binding
  • Issue 121 "Name of Template Medicine & specialized templates" with status "Open". Last event (2017-05-17T13:55:00):
  • Issue 122 "Typo in Description" with status "Closed". Last event (2016-03-01T12:56:49):
  • Issue 123 "epsos:asSpecializedKind/classCode" with status "Closed". Last event (2017-05-17T10:03:43):
    updated
  • Issue 124 "asSpecializedKind missing in Medication Summary Spec" with status "Open". Last event (2016-03-17T10:04:14):
  • Issue 125 "Fix statusCode definitions" with status "Closed". Last event (2015-12-02T22:50:41):
    Done
  • Issue 126 "Add 1.3.6.1.4.1.12559.11.10.1.3.1.3.1 template specializations" with status "Open". Last event (2016-07-13T16:42:19):
  • Issue 127 "manufacturedProduct/manufacturedMaterial/code remove voc binding" with status "Closed". Last event (2017-05-17T12:20:14):
    Removed the binding
  • Issue 128 "asSpecializedKind/epsos:generalizedMedicineClass/epsos:code voc binding missing" with status "Closed". Last event (2017-05-17T12:17:17):
    template upodated
  • Issue 129 "add manufacturedProduct/manufacturedMaterial/epsos:asSpecializedKind/epsos:generalizedMedicineClass/epsos:name element" with status "Closed". Last event (2017-05-17T13:46:38):
    template updated
  • Issue 130 "ingredient/[@classCode='ACTI']/ingredient/code element missing" with status "Closed". Last event (2017-05-17T12:15:49):
    Updated the template
  • Issue 131 "supply.code not foreseen" with status "Closed". Last event (2017-05-17T13:57:15):
    removed the voc binding
  • Issue 132 " hl7:effectiveTime datatype" with status "Closed". Last event (2017-05-17T14:24:28):
    added datatype and one example with the time stamp
  • Issue 133 "participantRole.id is optional" with status "Closed". Last event (2016-03-17T10:03:10):
    Added cardinality 0..*
  • Issue 134 "No devices example" with status "Open". Last event (2016-07-13T16:59:10):
    Improvement planned for the next template version (assigned to the label Template ID even if it is not related to this)
  • Issue 135 "Assign an epSOS specific template" with status "Open". Last event (2016-07-13T14:53:33):
  • Issue 136 "section.id optionality" with status "Closed". Last event (2017-05-17T13:37:16):
    Made Optional
  • Issue 137 "change oid of the template included for the organizer" with status "Open". Last event (2017-05-17T13:53:02):
  • Issue 138 "Add contrains for the organizer attributes" with status "Closed". Last event (2017-05-17T14:16:53):
    updated
  • Issue 139 "change the constrain about code@displayName" with status "Closed". Last event (2016-03-17T11:45:20):
    As epsom is multilingual, the constraint on having displayName valued as "Vital Signs" has been removed 
  • Issue 140 "Check effectivetime datatype" with status "Closed". Last event (2016-03-17T11:49:52):
    Added explanation and two examples
  • Issue 141 "change the reference for the Vital Signs Obs" with status "Closed". Last event (2016-03-17T11:13:08):
    Done
  • Issue 142 "Improve example, it is too generic." with status "Closed". Last event (2017-05-17T10:30:42):
    added id and effectiveTime
  • Issue 143 "Defunct Link to Template SimpleObservation" with status "Deferred". Last event (2017-05-17T11:18:28):
    No broken links in the template specifications; references to external templates used by /uses is not relevant for the time being . to be reconsidered for future consideration
  • Issue 144 "Relation Specialization defunct link" with status "Rejected". Last event (2017-05-17T10:35:07):
    Not clear what was the issue the 1.3.6.1.4.1.19376.1.5.3.1.3.11 is defined in the IHE PCC and it is the parent of this template
  • Issue 145 "Include footnote from Text Spec" with status "Closed". Last event (2017-05-17T10:15:05):
    Note added in the description
  • Issue 146 "Add epSOS unstructured document specifcations " with status "Closed". Last event (2017-05-17T09:59:45):
    Added proposal templates for unstructured documents
  • Issue 147 "Update document according to CP#08" with status "Open". Last event (2016-07-06T10:47:50):
    Finding:

    According to CP#8 the optionality R/R/RFNA shall be read as RNFA / RNFA / RNFA

    Suggestion:

    Update the work document consequently

  • Issue 148 "update specialty cardinality to 0..1" with status "Open". Last event (2016-07-06T10:49:40):
    Finding:

    Update Specialty cardinality to 0..1 (table in § 10.1)

    Suggestion:

    -

    Further explanation:

    -

  • Issue 149 "Value set 2.16.840.1.113883.1.11.19708 ActSubstanceAdministrationCode" with status "Closed". Last event (2017-05-17T09:57:34):
    Binding removed
  • Issue 150 "Fix participant role for agents" with status "Open". Last event (2017-05-17T14:49:33):
    TO BE FIXED creating a template fragment for agents
  • Issue 151 "statusCode cardinality to 1..1" with status "Closed". Last event (2017-05-17T09:54:40):
    fixed to 1..1
  • Issue 152 "IHE PCC templateId entry cannot be required" with status "Closed". Last event (2017-05-17T09:30:56):
    changed cardinality of the "other" templates to 0..1
  • Issue 153 "Example: Invalid XML" with status "Deferred". Last event (2017-05-17T14:52:25):
    no more able to see where the problem was...maybe it has been fixed
  • Issue 154 "Update the doseQuantity description " with status "Closed". Last event (2017-05-17T09:50:00):
    description updated
  • Issue 155 "Clarification on the usage of doseQuanity" with status "Closed". Last event (2017-05-17T09:51:17):
    Updated the doseQuantity description
  • Issue 156 "Assert not aligned with the error message" with status "Open". Last event (2017-05-17T14:54:30):
  • Issue 157 "Cardinality of the name prefix and suffix" with status "Closed". Last event (2017-11-15T17:00:10):
    This issue is related to issue 161 and the cardinality of the prefix/suffix is changed to 0 ... * (which is compliant with the HL7 CDA specifications)
  • Issue 158 "SignatureCode fixed to "S"" with status "Closed". Last event (2017-05-17T09:20:35):
    Added fixed code S
  • Issue 159 "relatedDocument cardinality" with status "Closed". Last event (2017-05-17T09:24:53):
    changed to 1...*
  • Issue 160 "Cardinality Contact/Preferred HP/Legal Organization" with status "In Progress". Last event (2017-05-17T14:53:57):
  • Issue 161 " (epSOSCDAauthor): prefix and suffix is required for assignedPerson" with status "Closed". Last event (2017-05-17T09:23:23):
    Changed the cardinailty for authior and legal auth.
  • Issue 162 "Check and update EDQM OID" with status "Closed". Last event (2017-11-15T15:30:33):
    Solved by the loading of the new MVC 2.2.2
  • Issue 163 "Check the binding with language VS" with status "Open". Last event (2017-05-17T14:53:29):
  • Issue 164 "realmCode" with status "Open". Last event (2017-07-18T23:26:34):
    Finding:

    -realmCode is Mandatory

    Suggestion:

    -change to 0..1 R

    Further explanation:

    -

  • Issue 165 "realmCode" with status "Open". Last event (2017-07-18T23:27:36):
    Finding:

    -is Mandatory

    Suggestion:

    --change to 0..1 R

    Further explanation:

    -

  • Issue 166 "realmCode" with status "Open". Last event (2017-07-18T23:26:57):
    Finding:

    -is mandatory

    Suggestion:

    --change to 0..1 R

    Further explanation:

    -

  • Issue 167 "realmCode" with status "Open". Last event (2017-07-18T23:28:55):
    Finding:

    -is mandatory

    Suggestion:

    --change to 0..1 R

    Further explanation:

    -

  • Issue 168 "realmCode" with status "Open". Last event (2017-07-18T23:28:19):
    Finding:

    -is Mandatory

    Suggestion:

    --change to 0..1 R

    Further explanation:

    -

  • Issue 169 "classCode, determinerCode" with status "Feedback needed". Last event (2017-07-18T23:01:19):
    proposal to close.

    I implemented the change. Expecting little effect, because it just removes (unnecessary) constraints.
  • Issue 170 "elements in address" with status "Open". Last event (2017-07-18T23:22:21):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    epSOS said for most address occurrences: "If there is no information, the nullFlavor attribute shall have a value of 'NI' and no address parts shall be present, otherwise there shall be no nullFlavor attribute, and at least one of the address parts listed below shall be present.". Only for Healthcare Facilities there are stricter rules (R1.10.9.3). From the information on optionality it can be inferred that the intention was to make only country mandatory here. Changed accordingly.

    -

  • Issue 171 "multiple instances of effectiveTime" with status "Open". Last event (2017-07-18T23:21:44):
    Finding:

    -validation fails for multiple effectiveTime instances. But epSOS requires two instances, at least in some cases. Note: this will probably be fixed by epsos-issue-101.

    Suggestion:

    - add more specific information on occurrence, like effectiveTime[1], effectiveTime[2] etc.

    Further explanation:

    -

  • Issue 172 "classCode, moodCode" with status "Rejected". Last event (2017-11-16T15:27:04):
    Change rejected. This is a specialization of Template CDA documentationOf (prototype, directly derived from POCD_RM000040 MIF).
  • Issue 173 "prefix/suffix required" with status "Closed". Last event (2017-11-16T15:38:54):
    Looks okay, is the same as the other person instances. Closed.
  • Issue 174 "Allow serviceEvent/effectiveTime as interval or TS?" with status "Open". Last event (2017-05-31T19:06:55):
    Finding:

    - EffectiveTime of ServiceEvent required Low and high

    Suggestion:

    - Modify template to allow for high only (without low) and also allow for TS, alternatively ("silent demotion")

    Further explanation:

    -

  • Issue 175 "OID for Comment Template" with status "Open". Last event (2017-06-08T13:01:07):
    Finding:

    The OID for the Comment Entry here is the same as for the IHE Comment Entry from PCC. You cannot use the same OID as it defines additional constraints here.

    Suggestion:

    Use the IHE Comment Entry as-is (ref) or clone it with a new template ID.

    Further explanation:

    -

  • Issue 176 "CDA Device : check value set binding with device.code" with status "Open". Last event (2017-06-12T17:44:51):
    Finding:

    To be evaluate if the value set indicated "The value of @code shall be drawn from value set  2.16.840.1.113883.1.11.16040 EntityCode  (DYNAMIC)" is here appropriate.

    Suggestion:

    -

    Further explanation:

    -

  • Issue 177 "Preferred Health Professional for emergency contact: change the classCode to ECON" with status "Open". Last event (2017-06-13T12:04:11):
    Finding:

    To describe the Preferred Health Professional for emergency contact is currently used participant/functionCode = PCP and particiapnt/associatedEntity@classCode="PRS"

    The usage of the classCode ECON seems to be more appropriate.

    Suggestion:

    -

    Further explanation:

    -

  • Issue 178 "No Entry?" with status "Open". Last event (2017-06-30T11:26:04):
    Which section Libor?
  • Issue 179 "generic template for simple observation is ill-defined" with status "Closed". Last event (2017-07-18T22:31:52):
    done.
  • Issue 180 "classCode is mandatory" with status "Open". Last event (2017-07-18T23:19:34):
    Finding:

    - classCode is mandatory, according to schema

    Suggestion:

    - change cardinality from 0..1 to 1..1

    Further explanation:

    -

  • Issue 181 "observation classCode is mandatory" with status "Open". Last event (2017-07-14T12:19:00):
    Finding:

    - observation classCode is mandatory

    Suggestion:

    - change cardinality to 1..1

    Further explanation:

    -

  • Issue 182 "change hl7:languageCode description" with status "Open". Last event (2017-07-14T12:20:15):
    Finding:

    At the moment the description is:
    Document Language Code
    • The language code SHALL be in the form nn-CC.
    • The nn portion SHALL be an ISO-639-1 language code in lower case derived by the Value Set epSOSLanguage.
    • The CC portion SHALL be an ISO-3166 country code in upper case derived by the value Set epSOSCountry
    Suggestion:

    Since MVC 2.2.1, the epSOSLanguage Value set contains already the languageCodes in the form nn-CC, so the hl7:languageCode won't be composed by the epSOSLanguage and the epSOSCountry codes with a hyphen in between.

    Further explanation:

    -

  • Issue 183 "LOINC code for blood group observation" with status "Open". Last event (2017-07-18T22:55:45):
    also see discussion on LOINC code in epsos-issue-192
  • Issue 184 "displayname and codesystem name are optional" with status "Open". Last event (2017-07-18T23:20:00):
    AFAIK the datatypes of such codes need to be CD.EPSOS rather than the generic CD
  • Issue 185 "Template is too specific" with status "Feedback needed". Last event (2017-07-19T11:25:51):
    The Coded Results Section template (1.3.6.1.4.1.12559.11.10.1.3.1.2.5) accepts only blood group observation ( 1.3.6.1.4.1.19376.1.5.3.1.4.13.6)  and no other observation entries . This requirement is listed as R18.1 and R18.2 in the PDF spec, and copied in the current template spec.
  • Issue 186 "allow for multiple entries" with status "Closed". Last event (2017-07-18T22:58:53):
    proposal to close issue. 

    implemented the proposed change, tests showed that it enables the documentation of both, closed and open Allergy Concerns in the same section.
  • Issue 187 "units in ingredient/quantity" with status "Feedback needed". Last event (2017-07-18T23:19:06):
    I'm not sure without re-reading our manual but I think if the binding is CWE a warning is generated instead of an error.
  • Issue 188 "Dosing-specific templates do not appear in template ID list" with status "Open". Last event (2017-07-18T15:21:05):
    Since this template needs to be revised in order to be specialized depending on the fact is used in a eP or into a PS.

    I Suggest to postpone this issue and when the revision will be done do no consider anymore these templates but use of the subordinated substance administration as suggested by the medication statement template defined by the Phama WG and adopted for the IPS
  • Issue 189 "correct OID for EDQM standard terms" with status "Closed". Last event (2017-11-15T15:29:22):
    Solved by the loading of the new MVC 2.2.2
  • Issue 190 " correct OID for EDQM standard terms" with status "Closed". Last event (2017-11-15T15:30:03):
    Solved by the loading of the new MVC 2.2.2
  • Issue 191 "correct OID for EDQM standard terms" with status "Closed". Last event (2017-11-15T15:28:50):
    Solved by the loading of the new MVC 2.2.2
  • Issue 192 "revert to original IHE template" with status "Feedback needed". Last event (2017-07-18T22:54:41):
    suggest to close issue, after discussion.
  • Issue 193 "empty template ID" with status "Closed". Last event (2017-07-18T22:53:14):
    change implemented
  • Issue 194 "template editor does not open" with status "Closed". Last event (2017-07-18T23:10:05):
    problem does not occur anymore, I was able to edit the template. issue solved.
  • Issue 195 "XML namespace for epSOS medication extensions" with status "Closed". Last event (2017-07-27T20:36:16):
    Changed to urn:epsos-org:ep:medication
  • Issue 196 "Fix some Cx.EPSOS DT definitions" with status "Closed". Last event (2017-07-22T11:39:45):
    Apologies, this was a documentation error and not a definition error. The documentation has been updated to reflect the current situation. Thanks for your patience.
  • Issue 197 "allow for multiple entries" with status "Open". Last event (2017-07-27T18:25:13):
    Finding:

    - cardinality of entry is 0..1

    Suggestion:

    - change to 0..*

    Further explanation:

    - good practice is to have one entry to contain one ProblemConcernAct, containing one Problem observation.

  • Issue 198 "allow for multiple entries" with status "Closed". Last event (2017-07-27T18:28:34):
    Finding:

    -section allows only 0..1 entry

    Suggestion:

    - change to 0..*

    Further explanation:

    - It is good practice that one entry contains one Act containing one Problem. So for multiple past illnesses we need multiple entries.

  • Issue 199 "doseQuantity: value set binding for units" with status "Open". Last event (2017-07-27T20:46:38):
    I suggest to remove the requirement to have a unit attribute.
    a) in the present form it precludes the use of IVL_PQ (with low and/or high elements)
    b) In section 11.1.1.2.3. of the PDF spec for the case of "countable items" it is stated that "In this case, only the unit count is specified , no units are specified." (which I prefer over the curly bracket kludge)
    c) the value set binding has to be discussed in the light of the option to use those curly brace expressions. Probably needs to be CWE, so we get schematron warnings, but not errors.
  • Issue 200 "value set for illnesses and disorders needs to be updated to four-digit ICD-10" with status "Closed". Last event (2017-07-27T21:54:44):
    Finding:

    - The current value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.5 does not reflect the most recent version of MVC

    Suggestion:

    - should be updated to contain 4 -digit ICD codes

    Further explanation:

    -

  • Issue 201 "Update to 4-char ICD" with status "Closed". Last event (2017-07-28T10:00:44):
    Finding:

    - Value set does not follow the updates in MVC

    Suggestion:

    - Suggest to update the value set.
    Please clarify with Solution Provider Terminology Expert how to proceed...

    Further explanation:

    -

  • Issue 202 "act.id conformance: not mandatory" with status "Closed". Last event (2017-08-01T18:32:51):
    Finding:

    - act.id is mandatory

    Suggestion:

    - change to 0..1 R

    Further explanation:

    - no reason to have it mandatory in base templates.

  • Issue 203 "editorial change: clarification concerning ActCode codesystem" with status "Closed". Last event (2017-08-01T18:56:13):
    Finding:

    - Description doesn't make it clear that codeSystem IHEActCode (1.3. 5.1.4.1.19376.1.5.3.2) must be used, and not generic HL7 ActCode (2.16.840.1.113883.5.4)

    Suggestion:

    - add text to clarify

    Further explanation:

    -

  • Issue 204 "id cardinality should be 0..1" with status "Closed". Last event (2017-08-01T19:09:19):
    Finding:

    - id cardinality is 1..1 R

    Suggestion:

    - id cardinality should be 0..1 R

    Further explanation:

    -

  • Issue 205 "id cardinality" with status "Open". Last event (2017-08-01T19:40:28):
    Finding:

    - is 1..1 R

    Suggestion:

    - should be 0..1 R

    Further explanation:

    -

  • Issue 206 "Define a specialized template for the agent" with status "Open". Last event (2017-09-05T12:04:37):
    Finding:
    hl7:participant
    0 … * C

    The substance that causes the allergy or intolerance shall be specified in the <participant> structure.

    The <code> element shall be present. It may contain a code and codeSystem attribute to indicate the code for the substance causing the allergy or intolerance. It shall contain a <reference> to the <originalText> in the narrative where the substance is named.


    Contains 2.16.840.1.113883.3.1937.777.11.10.134 CDA Participant (Body) (DYNAMIC)
    Suggestion:

    A specialized template should be defined for the <participant> structure describing the substance that causes the allergy or intolerance

    Further explanation:

    -

  • Issue 207 "Support for Multiple Active ingredient in ART-DECOR" with status "Closed". Last event (2017-10-12T16:05:22):
    Yes, it looks like an error in the current IG version. In the original PDF spec under rule R4.3 we see that manufacturedMaterial/ingredient/[@classCode='ACTI']/ingredient/name is on the same lavel as manufacturedMaterial/ingredient/[@classCode='ACTI']/ingredient/code

    Also, the levels of originalText and translation are strange. I believe they should be under manufacturedMaterial/ingredient/[@classCode='ACTI']/ingredient/code.

    I changed the template, moving originalText and translation under code, and moving name to the same level as code.
  • Issue 208 "Schema Error for draft element "hl7:desc" " with status "Closed". Last event (2017-10-27T16:22:22):
    Solved by changing the namespace prefix from hl7 to epsos
  • Issue 209 "Constraint applied to relatedDocument" with status "Open". Last event (2017-10-27T17:42:06):
    Finding:

    The CDA standard claims
    "A conformant CDA document can have a single relatedDocument with typeCode "APND"; a single relatedDocument with typeCode "RPLC"; a single relatedDocument with typeCode "XFRM"; a combination of two relatedDocuments with typeCodes "XFRM" and "RPLC"; or a combination of two relatedDocuments with typeCodes "XFRM" and "APND".

    No other combinations are allowed."

    Suggestion:

    This constraint is not captured by the current specifications.
    Add an explicit assertion to check this.

    Further explanation:

    -

  • Issue 210 "wrong cardinality of section/id" with status "In Progress". Last event (2017-10-28T00:14:23):
    Finding:

    - cardinality of id is 0..*

    Suggestion:

    - must be maximum 1. 
    Changed it to 0..1

    Further explanation:

    -

  • Issue 211 "statusCode cardinality wrong" with status "Closed". Last event (2017-10-28T09:59:41):
    Changed to 1..1
  • Issue 212 "cardinality of manufacturedProduct" with status "In Progress". Last event (2017-10-28T00:34:51):
    Finding:

    - cardinality of manufacturedProduct must be less or equal 1

    Suggestion:

    - Changed to 0...1

    Further explanation:

    -
    Test :  CDATEMP005(Validation Level : FLATTEN_4 , Type : ERROR) 
    Location :  //rules/template[14]/element[1]/element[16]/element[1] 
    CDALocation :  /hl7:substanceAdministration[hl7:templateId/@root='1.3.6.1.4.1.12559.11.10.1.3.1.3.2']/hl7:consumable/hl7:manufacturedProduct 
    Description :  The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005] 

  • Issue 213 "can not have more than one legalAuthenticator" with status "Closed". Last event (2017-10-28T10:02:51):
    If an artefact is locked but no longer used (e.g. if somebody opened the editor and simply clicked it away instead of closing it through the save or cancel buttons) the locks can be deleted by any project author through the Project -> Status tab.

    The cardinality has been changed to 1..1
  • Issue 214 "Base Standard Validation" with status "Open". Last event (2017-10-29T10:18:19):
    Finding:

    When <let> used, it shall not contains circular references to other <let> elements [HL7TEMP-045]  

    Suggestion:

    - more information needed.

    Further explanation:

    -

  • Issue 215 "effectiveTime maximum multiplicity " with status "Open". Last event (2017-10-29T10:25:38):
    Finding:

    - effectiveTime has cardinality 1..*

    Suggestion:

    -The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]  

    Further explanation:

    -

  • Issue 216 "text: maximum multiplicity" with status "In Progress". Last event (2017-10-29T10:28:05):
    Finding:

    - text cardinality is 1...*

    Suggestion:

    The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]

    Further explanation:

    -

  • Issue 217 "effectiveTime maximum multiplicity" with status "In Progress". Last event (2017-10-29T10:29:16):
    Finding:

    - effectiveTime is 1..*

    Suggestion:

    -The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]  

    Further explanation:

    -

  • Issue 218 "substanceAdministration maximum multiplicity" with status "In Progress". Last event (2017-10-29T10:59:01):
    Finding:

    - substanceAdministration maximum multiplicity is *

    Suggestion:

    The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]  

    Further explanation:

    -

  • Issue 219 "Constraints for custodian organization" with status "Open". Last event (2017-10-29T12:50:15):
    Finding:

    - The cardinality of custodian telecom is 0..* here, while it is constrained to 0..1 in the CDA Spec for custodiaon Org. Moreover, ID is mandatory for Custodian organisation.

    Suggestion:

    - cannot use the generic Organization template here. Adapt to additional constraints, specific for custodian organization.

    Further explanation:

    -

  • Issue 220 "see epsos-issue-219" with status "Open". Last event (2017-10-29T11:11:27):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    -

  • Issue 221 "can not have more than one legalAuthenticator" with status "In Progress". Last event (2017-10-29T11:12:49):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    -

  • Issue 222 "fix cardinality" with status "In Progress". Last event (2017-10-29T11:19:01):
    Finding:

    - cardinality is 0..*

    Suggestion:

    The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]  

    Further explanation:

    -

  • Issue 223 "fix cardinality" with status "Open". Last event (2017-10-29T11:22:06):
    Finding:

    -Test :  CDATEMP005(Validation Level : FLATTEN_4 , Type : ERROR) 

    Location :  //rules/template[31]/element[1]/element[10]/element[1]/element[3] 
    CDALocation :  /hl7:substanceAdministration[hl7:templateId/@root='1.3.6.1.4.1.19376.1.5.3.1.4.12']/hl7:consumable/hl7:manufacturedProduct/hl7:manufacturedMaterial 
    Description :  The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]  Suggestion:

    -

    Further explanation:

    -

  • Issue 224 "fix cardinality" with status "In Progress". Last event (2017-10-29T11:25:08):
    Finding:

    -Test :  CDATEMP005(Validation Level : FLATTEN_4 , Type : ERROR) 

    Location :  //rules/template[36]/element[1]/element[6] 
    CDALocation :  /hl7:observation[hl7:templateId/@root='1.3.6.1.4.1.19376.1.5.3.1.4.13.5']/hl7:effectiveTime 
    Description :  The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]  Suggestion:

    -

    Further explanation:

    -

  • Issue 225 "custodian org, see epsos-issue-219" with status "Open". Last event (2017-10-29T11:37:19):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    -

  • Issue 226 "fix cardinality of status code" with status "In Progress". Last event (2017-10-29T11:42:29):
    Finding:

    -Test :  CDATEMP005(Validation Level : FLATTEN_4 , Type : ERROR) 

    Location :  //rules/template[42]/element[1]/element[5] 
    CDALocation :  /hl7:act[hl7:templateId/@root='1.3.6.1.4.1.19376.1.5.3.1.4.3.1']/hl7:statusCode 
    Description :  The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]  Suggestion:

    -

    Further explanation:

    -

  • Issue 227 "custodian org, see epsos-issue-219" with status "Open". Last event (2017-10-29T11:44:51):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    -

  • Issue 228 "custodian org, see epsos-issue-219" with status "Open". Last event (2017-10-29T11:49:48):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    -

  • Issue 229 "custodian org, see epsos-issue-219" with status "Open". Last event (2017-10-29T11:57:11):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    -

  • Issue 230 "custodian org, see epsos-issue-219" with status "Open". Last event (2017-10-29T11:57:27):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    -

  • Issue 231 "participant: duplication of levels " with status "Open". Last event (2017-10-29T12:03:51):
    Finding:

    - The contains statement produces a duplication of the participant element (nesting).

    Suggestion:

    - replace "contains" by "include"?

    Further explanation:

    -

  • Issue 232 "participant duplication - see epsos-issue-231" with status "Open". Last event (2017-10-29T12:07:07):
    Finding:

    -

    Suggestion:

    -

    Further explanation:

    -

  • Issue 233 "Value Set differs from original normative CDA Spec" with status "Open". Last event (2017-10-30T13:56:47):
    sorry. The referenced value set is 2.16.840.1.113883.1.11.10901. And apparently it contains concepts that were not present in the original CDA vocabulary.

    The base standards validation complains:
    Test : CDATEMP019(Validation Level : FLATTEN_VOCAB , Type : FATALERROR) 
    Location : //rules/template[14]/element[1]/element[18]/attribute[1] 
    CDALocation : /hl7:substanceAdministration[hl7:templateId/@root='1.3.6.1.4.1.12559.11.10.1.3.1.3.2']/hl7:participant/@typeCode 
    Description : When a valueset is specified, and the referenced attribute is an enumeration, the content of the valueset SHALL be a restriction of the referenced attribute [CDATEMP-019] 
  • Issue 234 "The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]" with status "Closed". Last event (2017-10-31T08:55:15):
    I won't take any action on this:
    The template I changed ( 2.16.840.1.113883.3.1937.777.11.10.111 ) is the generic epSOSCDAOrganization, used for all kinds of Organizations.
    The bug was that Custodian should have a specialized template, more restrictive than the generic one that you changed.
  • Issue 235 "hl7:assignedPerson contains twice the element hl7:name" with status "In Progress". Last event (2017-10-31T18:09:56):
    The hl7:assignedPerson has a containment and and "overriding" inline definition. This is illegal. It should be either one.
    For the hl7:representedOrganization our recommendation is to name the representedOrganization element and the include the template (rather than contain).
    The same should be done for hl7:assignedPerson if appropriate.
  • Issue 236 "Relaxation of constraints for EntryAllergyAndIntolerance template" with status "Open". Last event (2017-11-03T11:18:21):
    Finding:

    In the Template EntryAllergyAndIntolerance   [1.3.6.1.4.1.19376.1.5.3.1.4.6]   in ART-DECOR, the hl7:id element is not consistent with the inheritance from the template Problem [1.3.6.1.4.1.19376.1.5.3.1.4.5]

    - The template EntryAllergyAndIntolerance   inherit from the template Problem, the template EntryAllergyAndIntolerance   says that hl7:id is 0..* , however the template Problem says that hl7:id is 1..1. This is not permitted to relax constraints.

    Suggestion:

    - Change the EntryAllergyAndIntolerance template and make the id a 1 ... 1 (with a conformance M?)

    Further explanation:

    -

2015‑11‑07 15:17:27 Dr. Kai U. Heitmann Official Release: 2014
Intermediate release before changes during the EXPAND update and review project: Formalization of epSOS Patient Summary, ePrescription and eDispensation documents using ART-DECOR
2014‑02‑28 Dr. Kai U. Heitmann (Nictiz) Corrected several templates that contained illegal spaces in OIDs or codes
2013‑12‑03 Alexander Henket (Nictiz) Review version for Giorgio Cangioli
2013‑06‑09 Alexander Henket (Nictiz) Extended data set, vocabulary, templates
2013‑06‑04 Tessa van Stijn (Nictiz) Added scenario and HL7 templates
2013‑05‑30 Maarten Ligtvoet (Nictiz) First concept of the epSOS decor file for demonstration purposes
2013‑05‑30 Elze de Groot (Nictiz) Added data set and vocabulary

Data sets, codes, OIDs and Rules: this information is used for rendering and validation purposes.